Home / Processes / Fire-neutral painting of wood, class D

Process 08 · Fire

Fire-neutral painting of wood, class D.

Ordinary paint that has been tested so that it can document that it does not ruin the fire class of an ordinary board of a specific wood species. This requires it to be documented how much paint has been applied per square metre.

Good to know about class D

Class D must also be documented.

Wood may only be used as class D in construction when it can be documented that the wood, with its surface treatment, meets class D. This also applies when the wood is painted with ordinary paint.

That is why we use specific products, and we document that they are applied in the approved quantity.

New rules from 2024

Changed
20 August 2024Commission Decision 2006/213/EC, and therefore also DS/EN 14915
Decision
2024/1399This is where the amendment is
Without testing
D-s2,d0and D-s2,d2, only for untreated solid wood as wall panels and wall cladding
Treated wood
SBI testeven when it is quite ordinary class D
Marking
CEwith the fire classification in the marking

For those of you designing timber facades

Class D must also be fire tested.

If you are designing timber facades, you should be aware that there are new rules from 2024 for timber cladding in solid wood, as the Commission Decision for the European classifications has been tightened.

Timber cladding with paint, other surface treatment, impregnation or modification can no longer be classified on the basis of the Commission Decision. The treated wood must be fire tested using the SBI test to document the fire classification.

Building materials must be CE-marked when they are covered by a European harmonised standard, and the fire classification must appear in the marking.

Commission Decision 2006/213/EC, and therefore also DS/EN 14915, was amended on 20 August 2024. It clarifies that the Commission Decision is limited to untreated wood. Only untreated solid wood can be classified without testing for use as wall panels and wall cladding as D-s2,d0 and D-s2,d2. See the amendment in Decision 2024/1399.

In future, treated wood must be fire tested in the European system, even when it is quite ordinary class D.

Does the wood need to reach class B? See fire-retardant coating of wood and fire-neutral painting of wood, class B.

Red-painted profiles on the roller conveyor
Painted profiles

Class D

Fire class
D
Paint
Ordinary paint, tested not to ruin the fire class
Application
Exterior cladding, ceilings, fixed furnishings and other interior cladding
Documentation
The wood species and the amount of paint per square metre
Testing
The SBI test in the European system
Marking
CE-marked with the fire classification
Max. dimensions
Traverse line: 1,250 × 9,000 × 70 mm
Profile line: 250 × 6,000 × 90 mm