Kolomore Get a quote

Home / Processes / Fire-neutral painting of wood, class B

Process 07 · Fire

Fire-neutral painting of wood, class B.

Burnblock-impregnated wood, painted with approved paint systems, in fire class B-s1,d0 and B-s2,d0 to EN 13501-1 for exterior cladding. Fire-neutral painting can also be used on ceilings, fixed furnishings and other interior cladding. Kolomore was the first in the world with a certificate for fire-retardant coating of Burnblock-impregnated wood and is still one of the few with CE certification to EN 14915.

CE certificate since
2021To EN 14915:2013, third-party certified
Fire class
B-s1,d0and B-s2,d0 to EN 13501-1
Wood species
15+including exotic and thermally modified
Paint systems
8+from five manufacturers
Combinations
120of wood species and paint system

The certificate follows the painted product

The fire class goes into the wood.

Scroll and follow a timber profile from impregnation to the building site.

A fire-protected profileIllustration: a timber profile is impregnated with Burnblock, kiln-dried and painted. The CE-marked profile can be cut to length and drilled, and the fire class stays with it.05 Cut and drilledThe class stays with itCEEN 14915B-s1,d001 The wood15+ wood species02 BurnblockImpregnated and kiln-dried03 PaintApproved paint system04 CE-markedB-s1,d0 or B-s2,d0

01 / 06 · The wood

Over 15 wood species.

The approval covers over 15 wood species, both common Nordic species and more exotic or thermally modified ones.

02 / 06 · Impregnation

Burnblock in the wood.

Development started at the beginning of 2020 in close collaboration with the Danish company Burnblock, which develops and produces non-toxic fire retardants.

03 / 06 · Kiln drying

An extra step.

The wood is impregnated and kiln-dried before painting. It is an extra step, and it takes a few weeks.

Infrared heaters glow orange inside the drying oven

04 / 06 · Painting

Over 8 paint systems.

Over 8 paints from Sherwin-Williams, Masquelack, SIOO:X, Tikkurila and Remmers. This gives 120 combinations in thousands of colours and effects.

05 / 06 · CE-marked

EN 14915.

In 2021, Kolomore obtained a CE certificate to EN 14915:2013 for painting timber profiles so that they meet the requirements for fire protection and smoke production for exterior cladding. Fire class B-s1,d0 and B-s2,d0 to EN 13501-1.

The flame image is from kolomore.com

Flames illustrating fire protection

06 / 06 · On site

Cut, drilled, installed.

The CE marking applies to the painted product as a construction product. The profiles can be cut to length, drilled and installed without losing their fire class, and you avoid an SBI test on a mock-up for each application.

For consultants and purchasing

Everything you need for the specification.

The first certificate covered 2 paint systems and 7 wood species. Today, the approval covers over 15 wood species combined with over 8 paints from Sherwin-Williams, Masquelack, SIOO:X, Tikkurila and Remmers. This gives 120 combinations in thousands of colours and effects.

The same CE certificate also covers the application of Teknos’ fire-retardant TEKNOSAFE systems. See fire-retardant coating of wood.

Application
Exterior cladding, ceilings, fixed furnishings and other interior cladding
Max. dimensions
Traverse line: 1,250 × 9,000 × 70 mm
Profile line: 250 × 6,000 × 90 mm
CE marking burnt into a fire-protected timber profile: B-s1,d0 to EN 14915
The CE marking on a fire-protected profile

Two routes to fire class B

Fire-neutral painting or fire-retardant coating.

The two systems suit different tasks. Here is the difference. Fire-retardant coating has its own page.

PropertyFire-neutral painting, class BBurnblock-impregnated woodFire-retardant coatingIntumescent paint
Fire classB-s1,d0 and B-s2,d0, CE-marked to EN 14915Up to B-s1,d0. CE-marked to EN 14915 on solid wood panelling and cladding with Teknos systems
SubstrateOver 15 wood species: Nordic, exotic and thermally modifiedIndoors, virtually any wood material: solid wood, MDF, OSB, plywood and glulam. Outdoors, fewer wood species, for example spruce and larch
ApplicationExterior cladding, ceilings, fixed furnishings and other interior claddingWalls, ceilings, fixed furnishings and furniture in larger building projects, and exterior cladding
On siteCan be cut to length, drilled and installed without losing the classCutting to length and adjusting destroy the fire protection, so cut surfaces must be touched up with fire-retardant paint on site
AppearanceThousands of colours and effects, including pre-weatheringAll RAL, NCS and custom colours as an opaque system. Outdoors, no translucent or transparent fire-retardant coatings and no patination
TimeAn extra step: the wood is impregnated and kiln-dried before painting, which takes a few weeksShorter lead time: the wood can come straight from the sawmill, and indoors wood in fire class D can become class B in a short time
Paint fromSherwin-Williams, Masquelack, SIOO:X, Tikkurila, RemmersTeknos, Sherwin-Williams, TREET, Masquelack

Class B on MDF

Fire-neutral painting of MDF, class B.

We have had our process fire tested, so we can supply a class B surface treatment in all colours and clear lacquer on fire-impregnated, class B MDF from 12 mm. The process combines UV roller coating as the primer and water-based spray painting as the topcoat, giving a furniture-quality surface in class B-s1,d0.

This applies to all MDF boards classified B-s1,d0, from any supplier. One SBI test is enough for us to sell the surface as B-s1,d0 under the standard. Before the system can be included in our CE marking, more fire tests must support the result.

This is relevant if you make shop fittings, for example.

See how the SBI test works.

The furniture system on MDF

Substrate
MDF boards classified B-s1,d0 from any supplier, from 12 mm
Topcoat
Water-based spray painting
Colours
All colours and clear lacquer
Fire class
B-s1,d0
Tested
SBI test to EN 13823 at MeKA, February 2026
CE
Not yet included in our CE marking. That requires more fire tests
Application
E.g. shop fittings

Selection guide

Find the right combination.

The guide is based on the appendices to our CE certificate, on Kolomore’s chart for wood that is not fire-impregnated, and on the SBI test of the furniture system on fire-impregnated MDF. Choose the wood, the thickness (for Burnblock-impregnated wood), whether it will be outdoors or indoors, and the fire class you need. It then shows the paint systems that fit.

The certificate is being updated. The new edition, 2412-CPR-1035-09, has been issued as a draft by Control Union and becomes valid once it is signed. The selection guide follows the appendices of the draft. The valid certificate is 1035-08 of 4 July 2025.

Without JavaScript, both charts and the furniture system on MDF are listed here, wood by wood. The fire class applies after painting and depends on the thickness of the wood.

Burnblock-impregnated wood

Spruce (Picea abies), pine (Pinus sylvestris), larch (Larix sibirica and Larix decidua), western red cedar (Thuja plicata), frake/limba (Terminalia superba), ayous (Triplochiton scleroxylon), ash (Fraxinus sp.) and Douglas fir (Pseudotsuga menziesii)

Surface
Planed, fine-sawn, paintcut or brushed
Application
Solid wood panels and cladding
Impregnation
Burnblock JG30, industrial vacuum-pressure impregnation at CE-certified subcontractors
Backing
A board of class A1 or A2-s1,d0, at least 12 mm and at least 525 kg/m³, or a fibre-cement board of class A2-s1,d0, at least 4.5 mm and at least 1,300 kg/m³
Air gap
Ventilated, non-ventilated or none. Battens of class D-s2,d0 or better
Mounting
Mechanical, vertical or horizontal
Without paint
B-s1,d0 at 15-50 mm and B-s2,d0 over 50 mm. Thermo poplar: B-s2,d0 and B-s3,d0
Tested to
EN 13501-1. CE to EN 14915 after painting, under certificate 2412-CPR-1035-09, which is a draft
Maintenance
Not covered by the CE certificate. What the cards say about maintenance comes from Kolomore’s chart. Ask us what applies to your system
  1. Outdoor only

    Sherwin-Williams System 1: SX1420 + EG1570

    1st coat primer SX1420, max. 62 g/m² wet. 2nd coat EG1570 with fungicide, max. 62 g/m² wet.

    Thickness and fire class after painting
    ThicknessFire class after painting
    18-42 mm, minimum profile 12 mmB-s1,d0
    Over 42 mmB-s2,d0
    Wood species
    Spruce, larch, pine, western red cedar, frake/limba, ayous, ash and Douglas fir
    Colours
    All opaque RAL, NCS or special colours and translucent colours
    After installation
    Can be maintained and keeps the fire class
    CE
    CE-marked to EN 14915 after painting. Certificate 2412-CPR-1035-09 (draft), appendix 1, table A1
  2. Indoor only

    Sherwin-Williams System 2: SX1420 + EG1170 (ECO)

    1st coat primer SX1420, max. 62 g/m² wet. 2nd coat EG1170 without fungicide, max. 62 g/m² wet.

    Thickness and fire class after painting
    ThicknessFire class after painting
    18-42 mm, minimum profile 12 mmB-s1,d0Blue in the chart: indoor
    Over 42 mmB-s2,d0
    Wood species
    Spruce, larch, pine, western red cedar, frake/limba, ayous, ash and Douglas fir
    Colours
    All opaque RAL, NCS or special colours and translucent colours
    After installation
    Can be maintained and keeps the fire class
    CE
    CE-marked to EN 14915 after painting. Certificate 2412-CPR-1035-09 (draft), appendix 1, table A1
  3. Indoor only

    Sherwin-Williams single-coat system: SX1420, EG1170 or EG1570

    All the coatings above can be used as a single-coat system with industrial application without affecting the fire class, max. 62 g/m² wet. Indoor, except EG1570. As a single-coat system, there may be restrictions on use.

    Thickness and fire class after painting
    ThicknessFire class after painting
    18-42 mm, minimum profile 12 mmB-s1,d0Blue in the chart: indoor
    Over 42 mmB-s2,d0
    Wood species
    Spruce, larch, pine, western red cedar, frake/limba, ayous, ash and Douglas fir
    Colours
    All RAL, NCS or special colours, clear colours (indoor only), translucent and certain metallic colours. Light and clear colours may not cover completely.
    After installation
    Wear layer with limited lifetime
    CE
    CE-marked to EN 14915 after painting. Certificate 2412-CPR-1035-09 (draft), appendix 1, table A1
  4. Outdoor only

    Masquelack Cosy Vintage

    Max. 42 g/m² ±10% wet.

    Thickness and fire class after painting
    ThicknessFire class after painting
    19-42 mmB-s1,d0
    Over 42 mmB-s2,d0
    Wood species
    Spruce, larch, pine, western red cedar, frake/limba, ayous and ash
    Colours
    The standard range Cottage, Cobalt, Cendre, Crecuscule, Café, Charbon, Camel, Cuir and Cohiba (in English: patina, cobalt, ash, dusk, coffee, coal, camel, leather and tobacco)
    After installation
    Decorative wear & tear treatment with limited lifetime
    CE
    CE-marked to EN 14915 after painting. Certificate 2412-CPR-1035-09 (draft), appendix 1, table A2
  5. Outdoor only

    SIOO:X Primer Wood Protector Industry and Surface Protector Industry

    2 coats of Primer Wood Protector Industry, max. 225 g/m² wet in total, and 1 coat of Surface Protector Industry, max. 115 g/m² wet.

    Thickness and fire class after painting
    ThicknessFire class after painting
    19-42 mmB-s1,d0
    Over 42 mmB-s2,d0
    Wood species
    Spruce, larch, pine, western red cedar, frake/limba, ayous and ash
    Colours
    Mid-Grey
    After installation
    Can be maintained, but loses the fire class
    CE
    CE-marked to EN 14915 after painting. Certificate 2412-CPR-1035-09 (draft), appendix 1, table B
  6. Outdoor only

    Tikkurila Pinja Protect GM

    1 coat of Pinja Protect GM, max. 120 g/m², or 2 coats of max. 120 g/m² each, max. 240 g/m² in total.

    Thickness and fire class after painting
    ThicknessFire class after painting
    22-42 mm, tongue and groove, minimum profile 13 mmB-s2,d0
    Over 42 mmB-s3,d0
    Fjällpanel with shiplap joint, 13-30 mm, profile as testedB-s2,d0
    Wood species
    Spruce, larch, pine, western red cedar, frake/limba, ayous and ash
    Colours
    All opaque RAL, NCS or special colours
    After installation
    Can be maintained and keeps the fire class
    CE
    CE-marked to EN 14915 after painting. Certificate 2412-CPR-1035-09 (draft), appendix 1, table D
  7. Outdoor only

    Remmers Induline for outdoor use: T-678 Plus or T-778 Plus

    2 coats of approx. 90 g/m² wet each, max. 180 g/m² in total, also as a single-coat system. T-678 Plus is opaque and T-778 Plus translucent, both with fungicide.

    Thickness and fire class after painting
    ThicknessFire class after painting
    18-42 mm, tongue and groove or shiplap, minimum profile 12 mmB-s2,d0
    Over 42 mmB-s3,d0
    Wood species
    Spruce, larch, pine, western red cedar, frake/limba, ayous, ash and Douglas fir
    Colours
    All colours
    After installation
    Ask us about maintenance
    CE
    CE-marked to EN 14915 after painting. Certificate 2412-CPR-1035-09 (draft), appendix 1, table E
  8. Indoor only

    Remmers Induline WF for indoor use: T-677 Plus WF or T-777 Plus WF

    2 coats of approx. 90 g/m² wet each, max. 180 g/m² in total, also as a single-coat system. T-677 Plus WF is opaque and T-777 Plus WF translucent, both without fungicide.

    Thickness and fire class after painting
    ThicknessFire class after painting
    18-42 mm, tongue and groove or shiplap, minimum profile 12 mmB-s2,d0Blue in the chart: indoor
    Over 42 mmB-s3,d0
    Wood species
    Spruce, larch, pine, western red cedar, frake/limba, ayous, ash and Douglas fir
    Colours
    All colours
    After installation
    Ask us about maintenance
    CE
    CE-marked to EN 14915 after painting. Certificate 2412-CPR-1035-09 (draft), appendix 1, table E

Thermally modified wood, Burnblock-impregnated

Thermo pine, thermo ash, thermo ayous, thermo spruce, thermo frake/limba, thermo poplar, thermo tulipwood (Liriodendron tulipifera) and thermo radiata pine (Pinus radiata)

Surface
Planed, fine-sawn, paintcut or brushed
Application
Solid wood panels and cladding
Impregnation
Burnblock JG30, industrial vacuum-pressure impregnation at CE-certified subcontractors
Backing
A board of class A1 or A2-s1,d0, at least 12 mm and at least 525 kg/m³, or a fibre-cement board of class A2-s1,d0, at least 4.5 mm and at least 1,300 kg/m³
Air gap
Ventilated, non-ventilated or none. Battens of class D-s2,d0 or better
Mounting
Mechanical, vertical or horizontal
Without paint
B-s1,d0 at 15-50 mm and B-s2,d0 over 50 mm. Thermo poplar: B-s2,d0 and B-s3,d0
Tested to
EN 13501-1. CE to EN 14915 after painting, under certificate 2412-CPR-1035-09, which is a draft
Maintenance
Not covered by the CE certificate. What the cards say about maintenance comes from Kolomore’s chart. Ask us what applies to your system
  1. Outdoor only

    Sherwin-Williams System 1: SX1420 + EG1570

    1st coat primer SX1420, max. 62 g/m² wet. 2nd coat EG1570 with fungicide, max. 62 g/m² wet.

    Thickness and fire class after painting
    ThicknessFire class after painting
    18-42 mm, minimum profile 12 mmB-s2,d0
    Over 42 mmB-s3,d0
    Wood species
    Thermo pine, thermo ash, thermo ayous, thermo spruce, thermo frake/limba, thermo poplar, thermo tulipwood and thermo radiata pine
    Colours
    All opaque RAL, NCS or special colours and translucent colours
    After installation
    Can be maintained and keeps the fire class
    CE
    CE-marked to EN 14915 after painting. Certificate 2412-CPR-1035-09 (draft), appendix 1, table A1
  2. Indoor only

    Sherwin-Williams System 2: SX1420 + EG1170 (ECO)

    1st coat primer SX1420, max. 62 g/m² wet. 2nd coat EG1170 without fungicide, max. 62 g/m² wet.

    Thickness and fire class after painting
    ThicknessFire class after painting
    18-42 mm, minimum profile 12 mmB-s2,d0
    Over 42 mmB-s3,d0
    Wood species
    Thermo pine, thermo ash, thermo ayous, thermo spruce, thermo frake/limba, thermo poplar, thermo tulipwood and thermo radiata pine
    Colours
    All opaque RAL, NCS or special colours and translucent colours
    After installation
    Can be maintained and keeps the fire class
    CE
    CE-marked to EN 14915 after painting. Certificate 2412-CPR-1035-09 (draft), appendix 1, table A1
  3. Indoor only

    Sherwin-Williams single-coat system: SX1420, EG1170 or EG1570

    All the coatings above can be used as a single-coat system with industrial application without affecting the fire class, max. 62 g/m² wet. Indoor, except EG1570. As a single-coat system, there may be restrictions on use.

    Thickness and fire class after painting
    ThicknessFire class after painting
    18-42 mm, minimum profile 12 mmB-s2,d0
    Over 42 mmB-s3,d0
    Wood species
    Thermo pine, thermo ash, thermo ayous, thermo spruce, thermo frake/limba, thermo poplar, thermo tulipwood and thermo radiata pine
    Colours
    All RAL, NCS or special colours, clear colours (indoor only), translucent and certain metallic colours. Light and clear colours may not cover completely.
    After installation
    Wear layer with limited lifetime
    CE
    CE-marked to EN 14915 after painting. Certificate 2412-CPR-1035-09 (draft), appendix 1, table A1
  4. Outdoor only

    Masquelack Cosy Vintage

    Max. 42 g/m² ±10% wet.

    Thickness and fire class after painting
    ThicknessFire class after painting
    19-42 mmB-s2,d0
    Over 42 mmB-s3,d0
    Wood species
    Thermo pine, thermo ash, thermo ayous, thermo spruce, thermo frake/limba, thermo poplar, thermo tulipwood and thermo radiata pine
    Colours
    The standard range Cottage, Cobalt, Cendre, Crecuscule, Café, Charbon, Camel, Cuir and Cohiba (in English: patina, cobalt, ash, dusk, coffee, coal, camel, leather and tobacco)
    After installation
    Decorative wear & tear treatment with limited lifetime
    CE
    CE-marked to EN 14915 after painting. Certificate 2412-CPR-1035-09 (draft), appendix 1, table A2
  5. Outdoor only

    SIOO:X Primer Wood Protector Industry and Surface Protector Industry

    2 coats of Primer Wood Protector Industry, max. 270 g/m² wet in total, and 1 coat of Surface Protector Industry, max. 115 g/m² wet.

    Thickness and fire class after painting
    ThicknessFire class after painting
    19-42 mmThermo pine, thermo ash, thermo ayous, thermo spruce, thermo frake/limba, thermo tulipwood and thermo radiata pineB-s1,d0
    Over 42 mmThermo pine, thermo ash, thermo ayous, thermo spruce, thermo frake/limba, thermo tulipwood and thermo radiata pineB-s2,d0
    19-42 mmThermo poplarB-s2,d0
    Over 42 mmThermo poplarB-s3,d0
    Wood species
    Thermo pine, thermo ash, thermo ayous, thermo spruce, thermo frake/limba, thermo poplar, thermo tulipwood and thermo radiata pine
    Colours
    The entire standard range from SIOO:X: clear, cloud grey 01, oyster grey 02, shark grey 03, fog grey 04, thunder grey 05, lava grey 06, black stone 07, almond brown 23 and walnut brown 27
    After installation
    Can be maintained, but loses the fire class
    CE
    CE-marked to EN 14915 after painting. Certificate 2412-CPR-1035-09 (draft), appendix 1, table B
  6. Outdoor only

    Remmers Induline for outdoor use: T-678 Plus or T-778 Plus

    2 coats of approx. 90 g/m² wet each, max. 180 g/m² in total, also as a single-coat system. T-678 Plus is opaque and T-778 Plus translucent, both with fungicide.

    Thickness and fire class after painting
    ThicknessFire class after painting
    18-42 mm, tongue and groove or shiplap, minimum profile 12 mmB-s2,d0
    Over 42 mmB-s3,d0
    Wood species
    Thermo pine, thermo ash, thermo ayous, thermo spruce, thermo frake/limba, thermo poplar, thermo tulipwood and thermo radiata pine
    Colours
    All colours
    After installation
    Ask us about maintenance
    CE
    CE-marked to EN 14915 after painting. Certificate 2412-CPR-1035-09 (draft), appendix 1, table E
  7. Indoor only

    Remmers Induline WF for indoor use: T-677 Plus WF or T-777 Plus WF

    2 coats of approx. 90 g/m² wet each, max. 180 g/m² in total, also as a single-coat system. T-677 Plus WF is opaque and T-777 Plus WF translucent, both without fungicide.

    Thickness and fire class after painting
    ThicknessFire class after painting
    18-42 mm, tongue and groove or shiplap, minimum profile 12 mmB-s2,d0Blue in the chart: indoor
    Over 42 mmB-s3,d0
    Wood species
    Thermo pine, thermo ash, thermo ayous, thermo spruce, thermo frake/limba, thermo poplar, thermo tulipwood and thermo radiata pine
    Colours
    All colours
    After installation
    Ask us about maintenance
    CE
    CE-marked to EN 14915 after painting. Certificate 2412-CPR-1035-09 (draft), appendix 1, table E

Plywood and glulam of pine, Burnblock-impregnated

Sanded plywood and glulam of pine

Surface
Sanded
  1. Indoor only

    BB lacquer

    Max. 2 x 90 g/m².

    Thickness and fire class after painting
    ThicknessFire class after painting
    Over 12 mmB-s1,d0Blue in the chart: indoor
    Colours
    Clear and translucent colours
    After installation
    Requires no maintenance, for indoor use only

Other wood or wood-based panels that have not been fire-retardant impregnated

Solid wood, MDF, OSB, plywood, glulam and much more

Solid wood, MDF, OSB, plywood, glulam and much more. The wood does not need fire-retardant impregnation. With fire-retardant paint, an intumescent paint, we can paint up to B-s1,d0. The paint is from Teknos, Sherwin-Williams, TREET and Masquelack. Cutting to length and adjusting on site destroy the fire protection, so cut surfaces must be touched up with fire-retardant paint on site. See fire-retardant coating of wood.

Fire class before painting
D-s2,d0
Mounting
Mechanical, vertical or horizontal
Density
Over 338 kg/m³. Timber battens: over 400 kg/m³
Backing
Over 12 mm A1 and A2-s1,d0, ventilated or non-ventilated depending on the system and number of painted sides. Timber battens: A2-s1,d0, non-ventilated
Tested to
EN 13501-1. CE to EN 14915 is shown for the systems our certificate covers. The others are fire tested but not CE-marked by us
Maintenance
Not covered by the CE certificate. What the cards say about maintenance comes from Kolomore’s chart. Ask us what applies to your system
  1. The chart does not say indoor or outdoor

    Teknos FR Panel system: TEKNOSAFE 2407 and TEKNOCLAD 3371

    Over 350 g/m² TEKNOSAFE 2407 on all sides and under 100 g/m² TEKNOCLAD 3371 as a topcoat on the visible sides.

    Wood, surface, thickness and fire class after painting
    Wood, surface and thicknessFire class after painting
    Solid spruce or spruce glulamPlaned, fine-sawn, paintcut or brushed. Over 19 and under 57 mmB-s1,d0 SP-105
    Colours
    All opaque colours
    Indoor
    Not applicable
    Durability
    EN 16755
    After installation
    Can be maintained and keeps the fire class
    CE
    CE-marked to EN 14915 after painting. Certificate 2412-CPR-1035-09 (draft), appendix 2: At least 350 g/m² TEKNOSAFE 2407-00 and 100 g/m² ±10% TEKNOCLAD 3370/3371: solid panelling and cladding of spruce with a fine-sawn surface, 19-57 mm with a minimum profile of 9.5 mm, for outdoor use
  2. Outdoor only

    Teknos FR Panel system: TEKNOSAFE 2407 and Flame Protect 2408

    At least 350 g/m² ±10% TEKNOSAFE 2407-00 as primer and 150 g/m² ±10% TEKNOSAFE Flame Protect 2408 as topcoat, measured wet. Teknol Aqua 1410-01 wood protection, 100-120 g/m², can be used under the primer.

    Wood, surface, thickness and fire class after painting
    Wood, surface and thicknessFire class after painting
    Solid spruceFine-sawn. 19-57 mm, minimum profile 9.5 mmB-s1,d0
    Colours
    All colours
    Indoor
    Not applicable
    After installation
    Ask us about maintenance
    CE
    CE-marked to EN 14915 after painting. Certificate 2412-CPR-1035-09 (draft), appendix 2: At least 350 g/m² TEKNOSAFE 2407-00 and 150 g/m² ±10% Flame Protect 2408: solid panelling and cladding of spruce with a fine-sawn surface, 19-57 mm with a minimum profile of 9.5 mm, for outdoor use
  3. The chart does not say indoor or outdoor

    Teknos FR Panel system: TEKNOSAFE 2407 and NORDICA ECO 3330-03

    Over 350 g/m² TEKNOSAFE 2407 on all sides and under 150 g/m² NORDICA ECO 3330-03 as a topcoat on the visible sides.

    Wood, surface, thickness and fire class after painting
    Wood, surface and thicknessFire class after painting
    Solid spruce or spruce glulamPlaned, fine-sawn, paintcut or brushed. Over 19 and under 57 mmB-s1,d0 SP-105
    Colours
    All opaque colours
    Indoor
    Not applicable
    Durability
    EN 16755
    After installation
    Can be maintained and keeps the fire class
    CE
    Not CE-marked by us. The fire tests that can classify the system exist
  4. The chart does not say indoor or outdoor

    TREET NORFLAM W312

    Over 350 g/m² on 4 sides.

    Wood, surface, thickness and fire class after painting
    Wood, surface and thicknessFire class after painting
    All wood species with a density over 338 kg/m³ and thermo pineFine-sawn and rough. Over 9 mmB-s1,d0
    Colours
    Coloured, semi-transparent
    Indoor
    Not applicable
    After installation
    Can be maintained and keeps the fire class
    CE
    Not CE-marked by us. The fire tests that can classify the system exist
  5. The chart does not say indoor or outdoor

    TREET NT Deco

    Over 350 g/m² on 4 sides.

    Wood, surface, thickness and fire class after painting
    Wood, surface and thicknessFire class after painting
    Any wood substrate with a density over 338 kg/m³, including CLT, LVL and glulamFine-sawn, rough, paintcut or coarsely sanded. Over 18 mmB-s1,d0
    Colours
    Coloured, semi-transparent or clear finish
    Indoor
    Not applicable
    After installation
    Can be maintained and keeps the fire class
    CE
    Not CE-marked by us. The fire tests that can classify the system exist
  6. Indoor only

    TREET NORFLAM W212

    Over 350 g/m² on 4 sides, or 3 sides without an air gap behind.

    Wood, surface, thickness and fire class after painting
    Wood, surface and thicknessFire class after painting
    MDF, plywood, OSB, oak, ash and pineFine-sawn, rough or paintcut. Over 9 mmB-s1,d0Blue in the chart: indoor
    Colours
    Many transparent colours and clear
    Indoor
    INT1/INT2
    After installation
    Requires no maintenance, for indoor use only
    CE
    Not CE-marked by us. The fire tests that can classify the system exist
  7. Indoor only

    TREET NT Deco

    Over 350 g/m² on 4 sides.

    Wood, surface, thickness and fire class after painting
    Wood, surface and thicknessFire class after painting
    Any wood substrate with a density over 338 kg/m³, including CLT, LVL and glulamFine-sawn, rough, paintcut or coarsely sanded. Over 18 mmB-s1,d0Blue in the chart: indoor
    Colours
    Coloured, semi-transparent or clear finish
    Indoor
    M1, LEED v4, BREEAM A+, AgBB
    After installation
    Requires no maintenance, for indoor use only
    CE
    Not CE-marked by us. The fire tests that can classify the system exist
  8. Indoor only

    TREET Norflam TP and NORFLAM TP01

    Over 200 g/m² Norflam TP on 4 sides and 220 g/m² NORFLAM TP01 on the visible side. Norflam TP only provides fire protection, not a resistant surface.

    Wood, surface, thickness and fire class after painting
    Wood, surface and thicknessFire class after painting
    Plywood, OSB, MDF and similarPlaned (and sanded), fine-sawn, paintcut or brushed. Over 9 mmB-s1,d0Blue in the chart: indoor
    Colours
    Clear base and coloured, semi-transparent or clear finish
    Indoor
    M1, Eurofins GOLD®
    After installation
    Requires no maintenance, for indoor use only
    CE
    Not CE-marked by us. The fire tests that can classify the system exist
  9. Indoor only

    Sherwin-Williams IM1000-0005

    Over 300 g/m² on 1 side.

    Wood, surface, thickness and fire class after painting
    Wood, surface and thicknessFire class after painting
    Plywood, pine and birchSanded. Over 12 mmB-s1,d0Blue in the chart: indoor
    Plywood, pine and birch, perforated Ø10 CC20Sanded. Over 12 mmB-s1,d0Blue in the chart: indoor
    OakPlaned. Over 16 mmB-s1,d0Blue in the chart: indoor
    Colours
    Clear and transparent colours
    After installation
    Requires no maintenance, for indoor use only
    CE
    Not CE-marked by us. The fire tests that can classify the system exist
  10. Indoor only

    Teknos TEKNOSAFE Flameguard 2467-10 and Flame Protect 2468-00

    Over 250 g/m² TEKNOSAFE Flameguard 2467-10 and under 100 g/m² TEKNOSAFE Flame Protect 2468-00.

    Wood, surface, thickness and fire class after painting
    Wood, surface and thicknessFire class after painting
    Any wood substrate with a density over 338 kg/m³, including CLT, LVL and glulamAll surfaces. Over 8 mmB-s1,d0Blue in the chart: indoor
    Colours
    Clear and transparent colours
    Indoor
    A+, M1, AgBB and Eurofins GOLD
    Durability
    EN 16755
    After installation
    Requires no maintenance, for indoor use only
    CE
    CE-marked to EN 14915 after painting. Certificate 2412-CPR-1035-09 (draft), appendix 2: solid panelling and cladding for indoor use, at least 250 g/m² Flame Guard 2467-10, without a topcoat or with Teknolux Aqua 1429, Uvilux 651, Teknocoat Aqua 2580, Teknocoat Aqua 1864, Flame Protect 2478-00 or Flame Protect 2468-00. Thickness and density as in the appendix: at least 18 mm and 433 kg/m³, at least 10 mm and 510 kg/m³, or at least 8 mm and 338 kg/m³ directly on a board
  11. Indoor only

    Teknos TEKNOSAFE Flameguard 2457-10 and Flame Protect 2458-00

    Over 250 g/m² TEKNOSAFE Flameguard 2457-10 and at most 100 g/m² TEKNOSAFE Flame Protect 2458-00, or one of the other topcoats in appendix 2.

    Wood, surface, thickness and fire class after painting
    Wood, surface and thicknessFire class after painting
    Any wood substrate with a density over 338 kg/m³, including CLT, LVL and glulamAll surfaces. Over 8 mmB-s1,d0Blue in the chart: indoor
    Colours
    All opaque colours
    Indoor
    A+, AgBB and Eurofins GOLD
    Durability
    EN 16755
    After installation
    Requires no maintenance, for indoor use only
    CE
    CE-marked to EN 14915 after painting. Certificate 2412-CPR-1035-09 (draft), appendix 2: solid panelling and cladding for indoor use, at least 250 g/m² Flame Guard 2457-10, without a topcoat or with Teknocoat Aqua 1864, Uvilux 651, Teknolux Aqua 1728, Teknocoat Aqua 2580, Teknocoat 1633 or Flame Protect 2458-00. Thickness and density as in the appendix: at least 18 mm and 433 kg/m³, at least 10 mm and 510 kg/m³, or at least 8 mm and 338 kg/m³ directly on a board
  12. The chart does not say indoor or outdoor

    TREET Thermoblack

    Over 350 g/m² on 4 sides.

    Wood, surface, thickness and fire class after painting
    Wood, surface and thicknessFire class after painting
    Thermo spruceFine-sawn and rough. Over 19 mmD-s1,d0
    Colours
    Black
    Indoor
    Not applicable
    After installation
    Can be maintained and keeps the fire class
    CE
    Not CE-marked by us. The fire tests that can classify the system exist
  13. The chart does not say indoor or outdoor

    TREET NORFLAM W313

    Over 250 g/m² on 3 sides.

    Wood, surface, thickness and fire class after painting
    Wood, surface and thicknessFire class after painting
    Thermo spruce and thermo pineFine-sawn and rough. Over 19 mmD-s1,d0
    Colours
    A limited selection of semi-transparent colours
    Indoor
    Not applicable
    After installation
    Can be maintained and keeps the fire class
    CE
    Not CE-marked by us. The fire tests that can classify the system exist
  14. Indoor only

    Teknos TEKNOSAFE Flameguard 2467-00, with or without Flame Protect 2468-00

    Over 250 g/m² TEKNOSAFE Flameguard 2467-00, with or without under 80 g/m² TEKNOSAFE Flame Protect 2468-00.

    Wood, surface, thickness and fire class after painting
    Wood, surface and thicknessFire class after painting
    Solid timber battens, 20 x 40 mmPlaned. Max. 1.72 m² visible surface per 1.0 m². 20 x 40 mmB-s1,d0Blue in the chart: indoor
    Colours
    Clear and transparent colours
    Indoor
    A+, M1, AgBB and Eurofins GOLD
    After installation
    Requires no maintenance, for indoor use only
    CE
    Not CE-marked by us. The fire tests that can classify the system exist
  15. Indoor only

    Teknos TEKNOSAFE Flameguard 2467-00 and Flame Protect 2468-00

    Over 250 g/m² TEKNOSAFE Flameguard 2467-00 and under 80 g/m² TEKNOSAFE Flame Protect 2468-00.

    Wood, surface, thickness and fire class after painting
    Wood, surface and thicknessFire class after painting
    Solid timber battens, 40 x 40 mmPlaned. Max. 1.72 m² visible surface per 1.0 m². 40 x 40 mmB-s1,d0Blue in the chart: indoor
    Colours
    Clear and transparent colours
    Indoor
    A+, M1, AgBB and Eurofins GOLD
    After installation
    Requires no maintenance, for indoor use only
    CE
    Not CE-marked by us. The fire tests that can classify the system exist

Fire-impregnated MDF in class B

MDF from 12 mm that is itself classified B-s1,d0, from any supplier, e.g. for shop fittings

We prime with UV roller coating and topcoat with water-based spray painting in all colours and clear lacquer. See fire-neutral painting of MDF.

Substrate
MDF boards classified B-s1,d0 from any supplier, from 12 mm
Topcoat
Water-based spray painting
Tested
SBI test to EN 13823 at MeKA, February 2026
CE
Not yet included in our CE marking. That requires more fire tests
  1. Indoor fittings and furniture

    Kolomore’s furniture system: UV primer and water-based topcoat

    Priming by UV roller coating and topcoat with water-based spray painting, giving a furniture-quality surface.

    Panel, thickness and fire class after painting
    Panel and thicknessFire class after painting
    MDF in class B-s1,d0, any supplierFrom 12 mmB-s1,d0
    Colours
    All colours and clear lacquer
    Application
    Indoor fittings and furniture, e.g. shop fittings
    Tested
    SBI test to EN 13823 at MeKA, February 2026
    CE
    Not yet included in our CE marking. That requires more fire tests
Kolomore’s chart of fire-approved paint systems by wood species, in English
Kolomore’s chart for Burnblock-impregnated wood from kolomore.com. The selection guide now follows the appendices to certificate 1035-09 (draft), so the figures may differ from the chart.

Do you need fire-classified wood?

Tell us about the project, the wood species and the fire class you need to achieve, and we will help you choose a system.

Get a quote
Bo Hjorth Jensen

Bo Hjorth Jensen founder and CEOCall +45 93 96 18 28Email bhj@kolomore.com

Business customers only. No sales to private customers